Project Description

ATMOSPHERE CONTROLLED
CHAMBER
FURNACE

TMAX 2800°C

Atmosphere controlled chamber furnace is designed for making heat treatment under the atmospheric conditions such as argon, nitrogen, vacuum, hydrogen etc.

PRODUCT SHEET
GET IN TOUCH
GO BACK

PRODUCT INFORMATION

Atmosphere Controlled Chamber Furnaces are used in applications such as manufacturing of metal products, heat-treatment, sintering, melting, ageing, thermal testing, powder synthesizing and chemical decomposition, where a protective environment is required within the furnaces to achieve the desired products. Atmosphere controlled chamber furnaces are designed for heat treatment under atmospheric conditions such as argon, nitrogen, vacuum, hydrogen and the like. In addition, water cooling system pressure, cabin temperature, internal atmospheric pressure, intelligent systems are monitored by the user to make the process is safe.

The adjustable manual gas flow meter, high-pressure relief system, overtemperature alarm and vacuum pump are integrated into the furnace as standard.

You can examine atmosphere controlled graphite furnaces for working with hydrogen atmosphere, better vacuum condition and metal samples, you can contact us for more information.

STANDARD FEATURES

  • Programmable step controller via digital display

  • Observation of set and real temperature

  • Delayed start and program save feature

  • Temperature control via PID and ±1°C temperature display sensitivity

  • System protection for over temperature,audio visual warning alarm

  • Temperature measurement via thermocouples

  • Error display in case a breakdown

  • Percentage of electrical energy consumption

  • Able to resume the program after the power failure

  • Exhaust gas outlet connected to inner volume

  • High-quality insulated heat zone

  • Low energy consumption

  • Automatic energy cut while lid opening and do not able to work unless lid is closed

  • 10-1 mbar standard vacuum pump with the purpose of purge the air

  • Protective gas inlet and outlet

  • Lid, gas and vacuum sensitivity, cooling cabin temperature alarm

  • Adjustable manual gas flowmeter

  • Sideways opening lid

  • Water cooled atmosphere cabin

  • Low external surface temperature (Ambient Temp. +40°C)
    thanks to double-layers steel construction

  • Epoxy painted galvanized-steel exterior

  • Height adjustable, non-slip rubber feet.

  • Usage with standing

OPTIONAL FEATURES

  • (DL) Data Logger

  • (G) Graphite resistance and graphite insulation

  • (PLC) PLC control and touch screen

  • (AVS) Auto vacuum and sweeping cycle

  • (MFC) Mass flow controller

  • (CH) Chiller

  • (PCC) PC Communication and Software

APPLICATION NOTES

For the maximum life of the furnace and the longer use of the furnace equipment, we recommend that the heating rate of 10°C/min should not exceed. For the fast heating and cooling features please contact us. Flammable and explosive products must not be used in the furnace.

The flowmeter which is included the furnace is manual but also not high sensitivity. For the higher sensitive ones please get in touch. The hydrogen gas usage inside the furnace must not exceed %8 and must be used as mixture gas. Please contact us for hydrogen gas. Gas, water source, furnace connections and connection equipment are to customers responsibility.

The vacuum pump is included in the system, for the purpose of purging the air. Vacuum pump doesn’t provide high vacuum condition. Please, you can contact us for high vacuum condition.

SERIES

Atmosphere controlled chamber furnaces are available in wide a ranges of volume and temperatures up to 2800°C continuous use. The standard models of atmosphere controlled chamber furnaces are listed below. Please contact us for detailed information.

  • ATM_1100

  • ATM_1600

  • ATM_1700

  • ATM_2200

TECHNICAL INFO CHARTS

You can see the technical info chart of atmosphere controlled chamber furnace series.

PRODUCT
CODE
MAX. TEMP.
°C
VOLUME
(L)
INTERNAL DIMENSIONS
Width
(mm)
Height
(mm)
Depth
(mm)
ATM_1100_411004150165165
ATM_1100_511005170170175
ATM_1100_811008200200200
ATM_1100_12110012200200300
ATM_1100_*1100****
*Produced on demand by the customer.
PRODUCT
CODE
MAX. TEMP.
°C
VOLUME
(L)
INTERNAL DIMENSIONS
Width
(mm)
Height
(mm)
Depth
(mm)
ATM_1600_416004140175165
ATM_1600_516005170175170
ATM_1600_816008180190245
ATM_1600_12160012200200300
ATM_1600_*1600****
*Produced on demand by the customer.
PRODUCT
CODE
MAX. TEMP.
°C
VOLUME
(L)
INTERNAL DIMENSIONS
Width
(mm)
Height
(mm)
Depth
(mm)
ATM_1700_417004150165165
ATM_1700_517005170170175
ATM_1700_817008180190245
ATM_1700_12170012200200300
ATM_1700_*1700****
*Produced on demand by the customer.
PRODUCT
CODE
MAX. TEMP.
°C
VOLUME
(L)
INTERNAL DIMENSIONS
Width
(mm)
Height
(mm)
Depth
(mm)
ATM_2200_522005170170175
ATM_2200_822008180190245
ATM_2200_12220012200200300
ATM_2200_*2200****
*Produced on demand by the customer.
GO BACK

Please follow us on social media for news & events.

UP TO 3000°C

HIGH-QUALITY
ENGINEERED FURNACES