Project Description
PRODUCT INFORMATION
Atmosphere Controlled Chamber Furnaces are used in applications such as manufacturing of metal products, heat-treatment, sintering, melting, ageing, thermal testing, powder synthesizing and chemical decomposition, where a protective environment is required within the furnaces to achieve the desired products. Atmosphere controlled chamber furnaces are designed for heat treatment under atmospheric conditions such as argon, nitrogen, vacuum, hydrogen and the like. In addition, water cooling system pressure, cabin temperature, internal atmospheric pressure, intelligent systems are monitored by the user to make the process is safe.
The adjustable manual gas flow meter, high-pressure relief system, overtemperature alarm and vacuum pump are integrated into the furnace as standard.
You can examine atmosphere controlled graphite furnaces for working with hydrogen atmosphere, better vacuum condition and metal samples, you can contact us for more information.
STANDARD FEATURES
Programmable step controller via digital display
Observation of set and real temperature
Delayed start and program save feature
Temperature control via PID and ±1°C temperature display sensitivity
System protection for over temperature,audio visual warning alarm
Temperature measurement via thermocouples
Error display in case a breakdown
Percentage of electrical energy consumption
Able to resume the program after the power failure
Exhaust gas outlet connected to inner volume
High-quality insulated heat zone
Low energy consumption
Automatic energy cut while lid opening and do not able to work unless lid is closed
10-1 mbar standard vacuum pump with the purpose of purge the air
Protective gas inlet and outlet
Lid, gas and vacuum sensitivity, cooling cabin temperature alarm
Adjustable manual gas flowmeter
Sideways opening lid
Water cooled atmosphere cabin
Low external surface temperature (Ambient Temp. +40°C)
thanks to double-layers steel constructionEpoxy painted galvanized-steel exterior
Height adjustable, non-slip rubber feet.
Usage with standing
OPTIONAL FEATURES
(DL) Data Logger
(G) Graphite resistance and graphite insulation
(PLC) PLC control and touch screen
(AVS) Auto vacuum and sweeping cycle
(MFC) Mass flow controller
(CH) Chiller
(PCC) PC Communication and Software
APPLICATION NOTES
For the maximum life of the furnace and the longer use of the furnace equipment, we recommend that the heating rate of 10°C/min should not exceed. For the fast heating and cooling features please contact us. Flammable and explosive products must not be used in the furnace.
The flowmeter which is included the furnace is manual but also not high sensitivity. For the higher sensitive ones please get in touch. The hydrogen gas usage inside the furnace must not exceed %8 and must be used as mixture gas. Please contact us for hydrogen gas. Gas, water source, furnace connections and connection equipment are to customers responsibility.
The vacuum pump is included in the system, for the purpose of purging the air. Vacuum pump doesn’t provide high vacuum condition. Please, you can contact us for high vacuum condition.
SERIES
Atmosphere controlled chamber furnaces are available in wide a ranges of volume and temperatures up to 2800°C continuous use. The standard models of atmosphere controlled chamber furnaces are listed below. Please contact us for detailed information.
ATM_1100
ATM_1600
ATM_1700
ATM_2200
TECHNICAL INFO CHARTS
You can see the technical info chart of atmosphere controlled chamber furnace series.
PRODUCT CODE | MAX. TEMP. °C | VOLUME (L) | INTERNAL DIMENSIONS | ||
---|---|---|---|---|---|
Width (mm) | Height (mm) | Depth (mm) |
|||
ATM_1100_4 | 1100 | 4 | 150 | 165 | 165 |
ATM_1100_5 | 1100 | 5 | 170 | 170 | 175 |
ATM_1100_8 | 1100 | 8 | 200 | 200 | 200 |
ATM_1100_12 | 1100 | 12 | 200 | 200 | 300 |
ATM_1100_* | 1100 | * | * | * | * |
*Produced on demand by the customer. |
PRODUCT CODE | MAX. TEMP. °C | VOLUME (L) | INTERNAL DIMENSIONS | ||
---|---|---|---|---|---|
Width (mm) | Height (mm) | Depth (mm) |
|||
ATM_1600_4 | 1600 | 4 | 140 | 175 | 165 |
ATM_1600_5 | 1600 | 5 | 170 | 175 | 170 |
ATM_1600_8 | 1600 | 8 | 180 | 190 | 245 |
ATM_1600_12 | 1600 | 12 | 200 | 200 | 300 |
ATM_1600_* | 1600 | * | * | * | * |
*Produced on demand by the customer. |
PRODUCT CODE | MAX. TEMP. °C | VOLUME (L) | INTERNAL DIMENSIONS | ||
---|---|---|---|---|---|
Width (mm) | Height (mm) | Depth (mm) |
|||
ATM_1700_4 | 1700 | 4 | 150 | 165 | 165 |
ATM_1700_5 | 1700 | 5 | 170 | 170 | 175 |
ATM_1700_8 | 1700 | 8 | 180 | 190 | 245 |
ATM_1700_12 | 1700 | 12 | 200 | 200 | 300 |
ATM_1700_* | 1700 | * | * | * | * |
*Produced on demand by the customer. |
PRODUCT CODE | MAX. TEMP. °C | VOLUME (L) | INTERNAL DIMENSIONS | ||
---|---|---|---|---|---|
Width (mm) | Height (mm) | Depth (mm) |
|||
ATM_2200_5 | 2200 | 5 | 170 | 170 | 175 |
ATM_2200_8 | 2200 | 8 | 180 | 190 | 245 |
ATM_2200_12 | 2200 | 12 | 200 | 200 | 300 |
ATM_2200_* | 2200 | * | * | * | * |
*Produced on demand by the customer. |