Project Description

ATMOSPHERE CONTROLLED
LIFT BOTTOM
FURNACE

TMAX 2800°C

Atmosphere controlled lift bottom furnaces are used in applications such as manufacturing of metal products, heat-treatment, sintering, melting, aging, thermal testing, powder synthesizing and chemical decomposition, where a protective environment is required within the furnaces to achieve the desired products.

PRODUCT SHEET
GET IN TOUCH
GO BACK

PRODUCT INFORMATION

Atmosphere controlled lift bottom furnace is preferred for where a protective environment is required such as manufacturing of metal products, heat-treatment, sintering, melting, ageing, thermal testing, powder synthesizing. As a result of these requirements, MSE has been designed and produced atmosphere controlled lift bottom furnace to make heat treatment under the protective atmospheric conditions such as argon, nitrogen, vacuum, hydrogen and the like.

MSE Furnace uses also cylindrical atmosphere cabins which are more stable than other geometries for atmosphere controlled lift-bottom furnace according to process. In addition, atmosphere controlled furnaces are water-cooled. So, water cooling system pressure, cabin temperature, internal atmospheric pressure, intelligent systems are monitored by the user to make the process is safe. And cabin of the furnace consists of heating elements and high-quality alumina refractories where selected according to the temperature. Lift bottom enables heavy and large samples to be placed more easily on the bottom of the furnace.

The adjustable manual gas flow meter, high-pressure relief system, overtemperature alarm and vacuum pump are integrated into the furnace as standard. For the Hydrogen atmosphere please contact us.

You can examine atmosphere controlled graphite furnaces for working with hydrogen atmosphere, better vacuum condition and metal samples, you can contact us for more information.

STANDARD FEATURES

  • Programmable step controller via digital display

  • Observation of set and real temperature

  • Delayed start and program save feature

  • Temperature control via PID and ±1°C temperature display sensitivity

  • System protection for over temperature, audio visual warning alarm

  • Temperature measurement via thermocouples

  • Error display in case a breakdown

  • Percentage of electrical energy consumption

  • Able to resume the program after the power failure

  • Heating on all side

  • Exhaust gas outlet connected to inner volume

  • High-quality insulated heat zone

  • Low energy consumption

  • Automatic energy cut while lift bottom opening and do not able to work unless lid is closed

  • 10-1 mbar standard vacuum pump with the purpose of purge the air

  • Protective gas inlet and outlet

  • Lid, gas and vacuum sensitivity, cooling cabin temperature alarm

  • Adjustable manual water flowmeter

  • Sample loading via lift bottom to the heat zone

  • Water cooled atmosphere cabin

  • Low external surface temperature (Ambient Temp. +40°C)
    thanks to double-layers steel construction

  • Epoxy painted galvanized-steel exterior

  • Height adjustable, non-slip rubber feet.

  • Usage with standing

OPTIONAL FEATURES

  • (DL) Data Logger

  • (G) Graphite resistance and graphite insulation

  • (PLC) PLC control and touch screen

  • (MFC) Mass flow control

  • (AVS) Auto vacuum and sweeping cycle

  • (CH) Chiller

  • (PCC) PC Communication and Software

APPLICATION NOTES

For the maximum life of the furnace and the longer use of the furnace equipment, we recommend that the heating rate of 10°C/min should not exceed. For the fast heating and cooling features please contact us. Flammable and explosive products must not be used in the furnace.

The flowmeter which is included the furnace is manual but also not high sensitivity. For the higher sensitive ones please get in touch. The hydrogen gas usage inside the furnace must not exceed %8 and must be used as mixture gas. Please contact us for hydrogen gas. Gas, water source, furnace connections and connection equipment are to customers responsibility.

The vacuum pump is included in the system, for the purpose of purging the air. Vacuum pump doesn’t provide high vacuum condition. Please, you can contact us for high vacuum condition.

SERIES

Atmosphere controlled lift bottom furnaces are available in wide a ranges of volume and temperatures up to 2800°C continuous use. The standard models of atmosphere controlled lift bottom furnaces are listed below. Please contact us for detailed information.

  • ATM_ELV_1100

  • ATM_ELV_1600

  • ATM_ELV_1700

  • ATM_ELV_1800

  • ATM_ELV_2200

TECHNICAL INFO CHARTS

You can see technical info chart of atmosphere controlled lift bottom furnaces series.

PRODUCT
CODE
MAX. TEMP.
°C
VOLUME
(L)
INTERNAL DIMENSIONS
Width
(mm)
Height
(mm)
Depth
(mm)
ATM_ELV_1100_411004150165165
ATM_ELV_1100_511005170170175
ATM_ELV_1100_811008200200200
ATM_ELV_1100_12110012200200300
ATM_ELV_1100_15110012200250300
ATM_ELV_1100_45110045360310410
ATM_ELV_1100_*1100****
*Produced on demand by the customer.
PRODUCT
CODE
MAX. TEMP.
°C
VOLUME
(L)
INTERNAL DIMENSIONS
Width
(mm)
Height
(mm)
Depth
(mm)
ATM_ELV_1600_416004140175165
ATM_ELV_1600_516005170175170
ATM_ELV_1600_816008180190245
ATM_ELV_1600_12160012200200300
ATM_ELV_1600_*1600****
*Produced on demand by the customer.
PRODUCT
CODE
MAX. TEMP.
°C
VOLUME
(L)
INTERNAL DIMENSIONS
Width
(mm)
Height
(mm)
Depth
(mm)
ATM_ELV_1700_417004150165165
ATM_ELV_1700_517005170170175
ATM_ELV_1700_817008180190245
ATM_ELV_1700_12170012200200300
ATM_ELV_1700_*1700****
*Produced on demand by the customer.
PRODUCT
CODE
MAX. TEMP.
°C
VOLUME
(L)
INTERNAL DIMENSIONS
Width
(mm)
Height
(mm)
Depth
(mm)
ATM_ELV_1800_4180043350350350
ATM_ELV_1800_*1800****
*Produced on demand by the customer.
PRODUCT
CODE
MAX. TEMP.
°C
VOLUME
(L)
INTERNAL
DIMENSIONS
Width
(mm)
Height
(mm)
Depth
(mm)
ATM_ELV_2200_522005170170175
ATM_ELV_2200_822008180190245
ATM_ELV_2200_12220012200200300
ATM_ELV_2200_*2200****
*Produced on demand by the customer.
GO BACK