Project Description
PRODUCT INFORMATION
Tube furnace is used to provide the desired atmosphere condition in a tube. In these furnaces, melting, thermal ageing, sintering, metal heat treatment, chemical decomposition, etc. can be made.
Tube of furnace must be preferred to according to the continuous using temperature of the furnace. This tubes can be quartz, mullite and alumina. In tube furnace, the horizontal or vertical operation, the tube rotating, tilt operation and feeding unit, creating and controlling the different temperature zones, measurement to the temperature of the sample with an external thermocouple from the inside of the tube, various optional features and vacuum can be selected.
Supply of tubes and accessories (flanges, ceramic crucibles etc.) can be obtained from our company.
STANDARD FEATURES
Programmable step controller via digital display
Observation of set and real temperature
Delayed start and program save feature
Temperature control via PID and ±1°C temperature display sensitivity
System protection for over temperature. Audio visual warning alarm
Temperature measurement via thermocouples
Error display in case a breakdown
Percentage of electrical energy consumption
Able to resume the program after the power failure
Heating on both side
High-quality insulated heat zone
Low energy consumption
Heat shields
Pulling and pushing wire for sample
Low external surface temperature (Ambient Temp. +40°C)
thanks to double-layers steel constructionEpoxy painted galvanized-steel exterior
Height adjustable, non-slip rubber feet.
OPTIONAL FEATURES
(V) Vacuum Pump
(FLN) Stainless steel gas inlet and outlet flanges**
(FR) Manual flowmeter
(Q) Quartz Tube
(M) Mullite Tube
(A) Alumina Tube
(D) Vertical Operation *
(R) Tube Rotation *
(WF) Product supply unit *
Independently Controllable: (Z2) 2 Zones, (Z3) 3 Zones, (Z4) 4 Zones *
(T) Tilted Operation
(ELV) Vertical Lift *
(MFC) Mass Flow Controller
(ET) The charge thermocouple
(WS) Standing
(PCC) PC Communication and Software
(DL) Data Logger
APPLICATION NOTES
For the maximum life of the furnace and the longer use of the furnace equipment, we recommend that the heating rate of 10°C/min should not exceed. If the alumina tube will be used, we recommended that the heating rate of 7 °C/min should not exceed. Flammable and explosive products must not be used in the furnace.
The flowmeter which is included the furnace is manual but also not high sensitivity. For the higher sensitive ones please get in touch.
The features which are signed with a star (*) may get change or not available according to the change on process necessity, volume, temperature and furnace model. (**) It may get change as water-cooled according to the temperature.
SERIES
Tube furnaces are manufactured in wide a range of diameters, different heating length and up to 1700°C continuous usage temperature. The standard models of split furnaces are listed below.
T_1100
T_1200
T_1400
T_1500
T_1600
T_1700
T_1750
TECHNICAL INFO CHARTS
You can see technical info chart of tube furnaces series.
PRODUCT CODE | MAX. TEMP. °C | INSIDE DIAMETER (mm) | HEATED LENGTH (mm) | TUBE |
---|---|---|---|---|
T_1100_20_250 | 1100 | 20 | 250 | Quartz |
T_1100_20_350 | 1100 | 20 | 350 | Quartz |
T_1100_20_450 | 1100 | 20 | 450 | Quartz |
T_1100_50_250 | 1100 | 50 | 250 | Quartz |
T_1100_50_350 | 1100 | 50 | 350 | Quartz |
T_1100_50_450 | 1100 | 50 | 450 | Quartz |
T_1100_50_600 | 1100 | 50 | 600 | Quartz |
T_1100_74_250 | 1100 | 74 | 250 | Quartz |
T_1100_74_450 | 1100 | 74 | 400 | Quartz |
T_1100_74_600 | 1100 | 74 | 600 | Quartz |
T_1100_100_250 | 1100 | 100 | 250 | Quartz |
T_1100_100_450 | 1100 | 100 | 450 | Quartz |
T_1100_150_250 | 1100 | 150 | 250 | Quartz |
T_1100_150_450 | 1100 | 150 | 450 | Quartz |
T_1100_200_450 | 1100 | 200 | 450 | Quartz |
T_1100_* | 1100 | * | * | Quartz |
*Produced on demand by the customer. |
PRODUCT CODE | MAX. TEMP. °C | INSIDE DIAMETER (mm) | HEATED LENGTH (mm) | TUBE |
---|---|---|---|---|
T_1200_20_250 | 1200 | 20 | 250 | Quartz |
T_1200_20_350 | 1200 | 20 | 350 | Quartz |
T_1200_20_450 | 1200 | 20 | 450 | Quartz |
T_1200_50_250 | 1200 | 50 | 250 | Quartz |
T_1200_50_350 | 1200 | 50 | 350 | Quartz |
T_1200_50_450 | 1200 | 50 | 450 | Quartz |
T_1200_50_600 | 1200 | 50 | 600 | Quartz |
T_1200_74_250 | 1200 | 74 | 250 | Quartz |
T_1200_74_450 | 1200 | 74 | 400 | Quartz |
T_1200_74_600 | 1200 | 74 | 600 | Quartz |
T_1200_* | 1200 | * | * | * |
*Produced on demand by the customer. |
PRODUCT CODE | MAX. TEMP. °C | INSIDE DIAMETER (mm) | HEATED LENGTH (mm) | TUBE |
---|---|---|---|---|
T_1400_20_250 | 1400 | 20 | 250 | Mullite |
T_1400_20_350 | 1400 | 20 | 350 | Mullite |
T_1400_20_450 | 1400 | 20 | 450 | Mullite |
T_1400_50_250 | 1400 | 50 | 250 | Mullite |
T_1400_50_350 | 1400 | 50 | 350 | Mullite |
T_1400_50_450 | 1400 | 50 | 450 | Mullite |
T_1400_50_600 | 1400 | 50 | 600 | Mullite |
T_1400_74_250 | 1400 | 74 | 250 | Mullite |
T_1400_74_450 | 1400 | 74 | 400 | Mullite |
T_1400_74_600 | 1400 | 74 | 600 | Mullite |
T_1400_* | 1400 | * | * | * |
*Produced on demand by the customer. |
PRODUCT CODE | MAX. TEMP. °C | INSIDE DIAMETER (mm) | HEATED LENGTH (mm) | TUBE |
---|---|---|---|---|
T_1500_40_250 | 1500 | 40 | 250 | Alumina |
T_1500_40_350 | 1500 | 40 | 350 | Alumina |
T_1500_40_450 | 1500 | 40 | 450 | Alumina |
T_1500_50_250 | 1500 | 50 | 250 | Alumina |
T_1500_50_350 | 1500 | 50 | 350 | Alumina |
T_1500_50_450 | 1500 | 50 | 450 | Alumina |
T_1500_50_600 | 1500 | 50 | 600 | Alumina |
T_1500_74_250 | 1500 | 74 | 250 | Alumina |
T_1500_74_450 | 1500 | 74 | 400 | Alumina |
T_1500_74_600 | 1500 | 74 | 600 | Alumina |
T_1500_* | 1500 | * | * | * |
*Produced on demand by the customer. |
PRODUCT CODE | MAX. TEMP. °C | INSIDE DIAMETER (mm) | HEATED LENGTH (mm) | TUBE |
---|---|---|---|---|
T_1600_40_350 | 1600 | 40 | 350 | Alumina |
T_1600_40_450 | 1600 | 40 | 450 | Alumina |
T_1600_50_350 | 1600 | 50 | 350 | Alumina |
T_1600_50_450 | 1600 | 50 | 450 | Alumina |
T_1600_50_600 | 1600 | 50 | 600 | Alumina |
T_1600_74_450 | 1600 | 74 | 450 | Alumina |
T_1600_74_600 | 1600 | 74 | 600 | Alumina |
T_1600_* | 1600 | * | * | * |
*Produced on demand by the customer. |
PRODUCT CODE | MAX. TEMP. °C | INSIDE DIAMETER (mm) | HEATED LENGTH (mm) | TUBE |
---|---|---|---|---|
T_1700_40_350 | 1700 | 40 | 350 | Alumina |
T_1700_40_450 | 1700 | 40 | 450 | Alumina |
T_1700_50_350 | 1700 | 50 | 350 | Alumina |
T_1700_50_450 | 1700 | 50 | 450 | Alumina |
T_1700_50_600 | 1700 | 50 | 600 | Alumina |
T_1700_74_450 | 1700 | 74 | 450 | Alumina |
T_1700_74_600 | 1700 | 74 | 600 | Alumina |
T_1700_* | 1700 | * | * | * |
*Produced on demand by the customer. |
PRODUCT CODE | MAX. TEMP. °C | INSIDE DIAMETER (mm) | HEATED LENGTH (mm) | TUBE |
---|---|---|---|---|
T_1750_40_350 | 1750 | 40 | 350 | Alumina |
T_1750_40_450 | 1750 | 40 | 450 | Alumina |
T_1750_50_350 | 1750 | 50 | 350 | Alumina |
T_1750_50_450 | 1750 | 50 | 450 | Alumina |
T_1750_50_600 | 1750 | 50 | 600 | Alumina |
T_1750_74_350 | 1750 | 74 | 350 | Alumina |
T_1750_74_450 | 1750 | 74 | 450 | Alumina |
T_1750_* | 1750 | * | * | * |
*Produced on demand by the customer. |